25 research outputs found

    Association of Ambulatory Hemodynamic Monitoring With Clinical Outcomes in a Concurrent Matched Control Analysis.

    Get PDF
    Importance: In a randomized clinical trial, heart failure (HF) hospitalizations were lower in patients managed with guidance from an implantable pulmonary artery pressure sensor compared with usual care. It remains unclear if ambulatory monitoring could also improve long-term clinical outcomes in real-world practice. Objective: To determine the association between ambulatory hemodynamic monitoring and rates of HF hospitalization at 12 months in clinical practice. Design, Setting, and Participants: This case-control study of Medicare beneficiaries used claims data collected between June 1, 2014, and March 31, 2016. Medicare patients who received implants of a pulmonary artery pressure sensor were identified from the 100% Medicare claims database. Each patient who received an implant was matched to a control patient by demographic features, history of HF hospitalization, and number of all-cause hospitalizations. Propensity scoring based on comorbidities (arrhythmia, hypertension, diabetes, pulmonary disease, and renal disease) was used for additional matching. Data analysis was completed from July 2017 through January 2019. Exposures: Implantable pulmonary artery pressure monitoring system. Main Outcomes and Measures: The rates of HF hospitalization were compared using the Andersen-Gill method. Days lost owing to events were compared using a nonparametric bootstrap method. Results: The study cohort consisted of 1087 patients who received an implantable pulmonary artery pressure sensors and 1087 matched control patients. The treatment and control cohorts were well matched by age (mean [SD], 72.7 [10.2] years vs 72.9 [10.1] years) and sex (381 of 1087 female patients [35.1%] in each group), medical history, comorbidities, and timing of preimplant HF hospitalization. At 12 months postimplant, 616 HF hospitalizations occurred in the treatment cohort compared with 784 HF hospitalizations in the control cohort. The rate of HF hospitalization was lower in the treatment cohort at 12 months postimplant (hazard ratio [HR], 0.76 [95% CI, 0.65-0.89]; P \u3c .001). The percentage of days lost to HF hospitalizations or death were lower in the treatment group (HR, 0.73 [95% CI, 0.64-0.84]; P \u3c .001) and the percentage of days lost owing to all-cause hospitalization or death were also lower (HR, 0.77 [95% CI, 0.68-0.88]; P \u3c .001). Conclusions and Relevance: Patients with HF who were implanted with a pulmonary artery pressure sensor had lower rates of HF hospitalization than matched controls and spent more time alive out of hospital. Ambulatory hemodynamic monitoring may improve outcomes in patients with chronic HF

    Non-culprit MACE-rate in LRP:The influence of optimal medical therapy using DAPT and statins

    Get PDF
    Background/Purpose: The Lipid Rich Plaque (LRP) study demonstrated the association between coronary plaque lipid content and outcomes. In this LRP substudy, we assessed the impact of optimal medical therapy (OMT) on the occurrence of non-culprit major adverse cardiac events (NC-MACE). Advanced intracoronary imaging modalities are able to identify patients with vulnerable coronary lesion morphology associated with future events. Methods/Materials: A total of 1270 patients who underwent cardiac catheterization for suspected coronary artery disease (CAD) with evaluable maxLCBI4mm in non-culprit vessels and known medical therapy after discharge were followed for 2 years. OMT was defined as the use of a statin and dual antiplatelet therapy (DAPT). Results: Among the 1270 patients included in this substudy, 1110 (87.7%) had PCI for an index event, and 1014 (80%) patients received OMT. Estimated cumulative incidence functions of NC-MACE did not differ significantly between patients treated with or without OMT (log-rank p-value = 0.876). In patients labeled high risk (maxLCBI4mm > 400), cumulative incidence function also did not differ between patients treated with vs without OMT (log-rank p-value = 0.19). Conclusions: In the current LRP analysis, we could not identify a beneficial effect of OMT in the reduction of NC-MACE rate, even in patients with high-risk plaques during 24-month follow-up

    Predicting future left anterior descending artery events from non-culprit lesions:insights from the Lipid-Rich Plaque study

    Get PDF
    AIMS: The left anterior descending (LAD) artery is the most frequently affected site by coronary artery disease. The prospective Lipid Rich Plaque (LRP) study, which enrolled patients undergoing imaging of non-culprits followed over 2 years, reported the successful identification of coronary segments at risk of future events based on near-infrared spectroscopy-intravascular ultrasound (NIRS-IVUS) lipid signals. We aimed to characterize the plaque events involving the LAD vs. non-LAD segments. METHODS AND RESULTS: LRP enrolled 1563 patients from 2014 to 2016. All adjudicated plaque events defined by the composite of cardiac death, cardiac arrest, non-fatal myocardial infarction, acute coronary syndrome, revascularization by coronary bypass or percutaneous coronary intervention, and rehospitalization for angina with >20% stenosis progression and reported as non-culprit lesion-related major adverse cardiac events (NC-MACE) were classified by NIRS-IVUS maxLCBI4 mm (maximum 4-mm Lipid Core Burden Index) ≤400 or >400 and association with high-risk-plaque characteristics, plaque burden ≥70%, and minimum lumen area (MLA) ≤4 mm2. Fifty-seven events were recorded with more lipid-rich plaques in the LAD vs. left circumflex and right coronary artery; 12.5% vs. 10.4% vs. 11.3%, P = 0.097. Unequivocally, a maxLCBI4 mm >400 in the LAD was more predictive of NC-MACE [hazard ratio (HR) 4.32, 95% confidence interval (CI) (1.93-9.69); P = 0.0004] vs. [HR 2.56, 95% CI (1.06-6.17); P = 0.0354] in non-LAD segments. MLA ≤4 mm2 within the maxLCBI4 mm was significantly higher in the LAD (34.1% vs. 25.9% vs. 13.7%, P < 0.001). CONCLUSION: Non-culprit lipid-rich segments in the LAD were more frequently associated with plaque-level events. LAD NIRS-IVUS screening may help identify patients requiring intensive surveillance and medical treatment

    Multi-probe analysis of the galaxy cluster CL J1226.9+3332: Hydrostatic mass and hydrostatic-To-lensing bias

    Get PDF
    The precise estimation of the mass of galaxy clusters is a major issue for cosmology. Large galaxy cluster surveys rely on scaling laws that relate cluster observables to their masses. From the high-resolution observations of ∼45 galaxy clusters with the NIKA2 and XMM-Newton instruments, the NIKA2 Sunyaev-Zela'dovich Large Program should provide an accurate scaling relation between the thermal Sunyaev-Zela'dovich effect and the hydrostatic mass. In this paper we present an exhaustive analysis of the hydrostatic mass of the well-known galaxy cluster CL J1226.9+3332, the highest-redshift cluster in the NIKA2 Sunyaev-Zela'dovich Large Program at z=0.89. We combined the NIKA2 observations with thermal Sunyaev-Zela'dovich data from the NIKA, Bolocam, and MUSTANG instruments and XMM-Newton X-ray observations, and tested the impact of the systematic effects on the mass reconstruction. We conclude that slight differences in the shape of the mass profile can be crucial when defining the integrated mass at R500, which demonstrates the importance of the modelling in the mass determination. We prove the robustness of our hydrostatic mass estimates by showing the agreement with all the results found in the literature. Another key factor for cosmology is the bias of the masses estimated assuming the hydrostatic equilibrium hypothesis. Based on the lensing convergence maps from the Cluster Lensing And Supernova survey with Hubble (CLASH) data, we obtain the lensing mass estimate for CL J1226.9+3332. From this we are able to measure the hydrostatic-To-lensing mass bias for this cluster, which spans from 1-bHSE/lens∼0.7 to 1, presenting the impact of data sets and mass reconstruction models on the bias

    On-Orbit Performance of the Far Ultraviolet Spectroscopic Explorer (FUSE) Satellite

    Get PDF
    Launch of the Far Ultraviolet Spectroscopic Explorer (FUSE) has been followed by an extensive period of calibration and characterization as part of the preparation for normal satellite operations. Major tasks carried out during this period include initial coalignment, focusing and characterization of the four instrument channels, and a preliminary measurement of the resolution and throughput performance of the instrument. We describe the results from this test program, and present preliminary estimates of the on-orbit performance of the FUSE satellite based on a combination of this data and prelaunch laboratory measurements.Comment: 8 pages, including 3 figures. This paper will appear in the FUSE special issue of ApJ Letter

    Omecamtiv mecarbil in chronic heart failure with reduced ejection fraction, GALACTIC‐HF: baseline characteristics and comparison with contemporary clinical trials

    Get PDF
    Aims: The safety and efficacy of the novel selective cardiac myosin activator, omecamtiv mecarbil, in patients with heart failure with reduced ejection fraction (HFrEF) is tested in the Global Approach to Lowering Adverse Cardiac outcomes Through Improving Contractility in Heart Failure (GALACTIC‐HF) trial. Here we describe the baseline characteristics of participants in GALACTIC‐HF and how these compare with other contemporary trials. Methods and Results: Adults with established HFrEF, New York Heart Association functional class (NYHA) ≥ II, EF ≤35%, elevated natriuretic peptides and either current hospitalization for HF or history of hospitalization/ emergency department visit for HF within a year were randomized to either placebo or omecamtiv mecarbil (pharmacokinetic‐guided dosing: 25, 37.5 or 50 mg bid). 8256 patients [male (79%), non‐white (22%), mean age 65 years] were enrolled with a mean EF 27%, ischemic etiology in 54%, NYHA II 53% and III/IV 47%, and median NT‐proBNP 1971 pg/mL. HF therapies at baseline were among the most effectively employed in contemporary HF trials. GALACTIC‐HF randomized patients representative of recent HF registries and trials with substantial numbers of patients also having characteristics understudied in previous trials including more from North America (n = 1386), enrolled as inpatients (n = 2084), systolic blood pressure &lt; 100 mmHg (n = 1127), estimated glomerular filtration rate &lt; 30 mL/min/1.73 m2 (n = 528), and treated with sacubitril‐valsartan at baseline (n = 1594). Conclusions: GALACTIC‐HF enrolled a well‐treated, high‐risk population from both inpatient and outpatient settings, which will provide a definitive evaluation of the efficacy and safety of this novel therapy, as well as informing its potential future implementation

    Predicting future left anterior descending artery events from non-culprit lesions: insights from the Lipid-Rich Plaque study

    No full text
    AIMS: The left anterior descending (LAD) artery is the most frequently affected site by coronary artery disease. The prospective Lipid Rich Plaque (LRP) study, which enrolled patients undergoing imaging of non-culprits followed over 2 years, reported the successful identification of coronary segments at risk of future events based on near-infrared spectroscopy-intravascular ultrasound (NIRS-IVUS) lipid signals. We aimed to characterize the plaque events involving the LAD vs. non-LAD segments. METHODS AND RESULTS: LRP enrolled 1563 patients from 2014 to 2016. All adjudicated plaque events defined by the composite of cardiac death, cardiac arrest, non-fatal myocardial infarction, acute coronary syndrome, revascularization by coronary bypass or percutaneous coronary intervention, and rehospitalization for angina with >20% stenosis progression and reported as non-culprit lesion-related major adverse cardiac events (NC-MACE) were classified by NIRS-IVUS maxLCBI4 mm (maximum 4-mm Lipid Core Burden Index) ≤400 or >400 and association with high-risk-plaque characteristics, plaque burden ≥70%, and minimum lumen area (MLA) ≤4 mm2. Fifty-seven events were recorded with more lipid-rich plaques in the LAD vs. left circumflex and right coronary artery; 12.5% vs. 10.4% vs. 11.3%, P = 0.097. Unequivocally, a maxLCBI4 mm >400 in the LAD was more predictive of NC-MACE [hazard ratio (HR) 4.32, 95% confidence interval (CI) (1.93-9.69); P = 0.0004] vs. [HR 2.56, 95% CI (1.06-6.17); P = 0.0354] in non-LAD segments. MLA ≤4 mm2 within the maxLCBI4 mm was significantly higher in the LAD (34.1% vs. 25.9% vs. 13.7%, P < 0.001). CONCLUSION: Non-culprit lipid-rich segments in the LAD were more frequently associated with plaque-level events. LAD NIRS-IVUS screening may help identify patients requiring intensive surveillance and medical treatment

    Exome sequencing analysis reveals variants in primary immunodeficiency genes in patients with very early onset inflammatory bowel disease

    No full text
    Very early onset inflammatory bowel disease (VEO-IBD), IBD diagnosed ≤5 y of age, frequently presents with a different and more severe phenotype than older-onset IBD. We investigated whether patients with VEO-IBD carry rare or novel variants in genes associated with immunodeficiencies that might contribute to disease development

    Identification of patients and plaques vulnerable to future coronary events with near-infrared spectroscopy intravascular ultrasound imaging: a prospective, cohort study

    No full text
    Background: Near-infrared spectroscopy (NIRS) intravascular ultrasound imaging can detect lipid-rich plaques (LRPs). LRPs are associated with acute coronary syndromes or myocardial infarction, which can result in revascularisation or cardiac death. In this study, we aimed to establish the relationship between LRPs detected by NIRS-intravascular ultrasound imaging at unstented sites and subsequent coronary events from new culprit lesions. Methods: In this prospective, cohort study (LRP), patients from 44 medical centres were enrolled in Italy, Latvia, Netherlands, Slovakia, UK, and the USA. Patients with suspected coronary artery disease who underwent cardiac catheterisation with possible ad hoc percutaneous coronary intervention were eligible to be enrolled. Enrolled patients underwent scanning of non-culprit segments using NIRS-intravascular ultrasound imaging. The study had two hierarchal primary hypotheses, patient and plaque, each testing the association between maximum 4 mm Lipid Core Burden Index (maxLCBI4mm) and non-culprit major adverse cardiovascular events (NC-MACE). Enrolled patients with large LRPs (≥250 maxLCBI4mm) and a randomly selected half of patients with small LRPs (<250 maxLCBI4mm) were followed up for 24 months. This study is registered with ClinicalTrials.gov, NCT02033694. Findings: Between Feb 21, 2014, and March 30, 2016, 1563 patients were enrolled. NIRS-intravascular ultrasound device-related events were seen in six (0·4%) patients. 1271 patients (mean age 64 years, SD 10, 883 [69%] men, 388 [31%]women) with analysable maxLCBI4mm were allocated to follow-up. The 2-year cumulative incidence of NC-MACE was 9% (n=103). Both hierarchical primary hypotheses were met. On a patient level, the unadjusted hazard ratio (HR) for NC-MACE was 1·21 (95% CI 1·09–1·35; p=0·0004) for each 100-unit increase maxLCBI4mm) and adjusted HR 1·18 (1·05–1·32; p=0·0043). In patients with a maxLCBI4mm more than 400, the unadjusted HR for NC-MACE was 2·18 (1·48–3·22; p<0·0001) and adjusted HR was 1·89 (1·26–2·83; p=0·0021). At the plaque level, the unadjusted HR was 1·45 (1·30–1·60; p<0·0001) for each 100-unit increase in maxLCBI4mm. For segments with a maxLCBI4mm more than 400, the unadjusted HR for NC-MACE was 4·22 (2·39–7·45; p<0·0001) and adjusted HR was 3·39 (1·85–6·20; p<0·0001). Interpretation: NIRS imaging of non-obstructive territories in patients undergoing cardiac catheterisation and possible percutaneous coronary intervention was safe and can aid in identifying patients and segments at higher risk for subsequent NC-MACE. NIRS-intravascular ultrasound imaging adds to the armamentarium as the first diagnostic tool able to detect vulnerable patients and plaques in clinical practice. Funding: Infraredx
    corecore